1. RESTRICTION:

Use 5mg genomic DNA for Southern hybridization.

Aliquot DNA in H20: Total Vol 100l .

Add 100l Mix.

TOTAL VOL: 200l

MIX:            Add 100 units per sample of each restriction enzyme.

Add appropriate buffer (10X)--20l for each reaction

Add BSA, if needed (100X)----2l for each reaction

Then, add H20 for total volume of 100l for each reaction.

Example:     SacI (20u/l ): 5l

NotI(10u/l ): 10l

Buffer1(10X): 20l

BSA(100X): 2l

H20: 63l

Incubate overnight at 37° C (or appropriate temp.)  in water bath.

2. PRECIPITATION:

Quick spin DNA

Then, add 245l Mix of salt & H20 (200l H2O + 45l 3M Na Acetate): Add 2l glycogen

Fill eppendorf to top with 100% EtOH

Ppt either at -20° C overnight or in dry ice for 30min or -70° C for 30min (STABLE---can store)

3. WASH:

Vortex 5sec

Spin for 30 min at 1350 rpm in cold room

Discard EtOH.

Add 70% EtOH to 1/2 fill eppendorf. Vortex 5sec.

Spin 10 min at 1350 rpm. Discard EtOH

Quick spin.

Remove excess remaining EtOH using P200 pipette.

Air Dry 10 min

Add 20l 1X loading buffer (Stock 6X)

Heat 15-30 min at 50° C

Load 20l /well. First vortex, then quick spin each sample.

4. PREPARING GELS: While samples are spinning, prepare gels (Vertical Hoefer apparatus, 3mm thick gels):

APPARATUS ASSEMBLY: Take 2 clean glass plates. Put white marker and spacer on each end (3mm), then place on flat area and tighten. Place plates in apparatus and tighten with black plugs. Place 1/2 in tape around top of 3mm comb to decrease well size and place comb in apparatus.

PLUG PREPARATION: Prepare 5cc per gel

Bis-acrylamide (19.5:1) : 2.5cc

H2O : 2.5cc

TEMED : 15l

APS :150l

Pour 4cc in each apparatus. It will solidify in 3-5min.

GEL PREPARATION: Prepare 1% agarose gel in 1X TAE. Use 1g agarose in 100cc 1X TAE (without EB). Microwave. Cool to 80-90° C. Pour 100cc rapidly into apparatus. Use a transfer pipette (with top & bottom cut-off) to facilitate rapid pouring.. Add additional solution for next 5minutes around comb sites to prevent bubbles. Cool at room temperature for 1hour.

Remove comb gently out of gel apparatus by gently sliding back and forth. Clear top of each apparatus and remove excess gel by using a scalpel and clean each well with a toothpick.

Assemble gel for Southern by placing buffer well on top of gel and tightening with black plugs. Pour 1X TAE buffer in well box and make sure it does not leak.

Remove gel from stand and place in Hoefer apparatus. Fill Hoefer with 1X TAE buffer.

5. GEL LOADING:

Load 20l / well. First vortex then quick spin each sample before loading

6. ELECTROPHORESIS:

Run at 45V for 20minutes, then 80V for 1hour and then 90V until samples have run about 9cm from well.

Total running time: app 3hours

7. STAINING:

Remove gel from apparatus.

Mark lower right-sided corner for gel#1 and top & lower right-sided corner for gel #2.

Stain with ethidium bromide solution for 10 minutes in 500cc solution (100l in 1L)

Discard and rinse with H2O.

Expose film in dark room with eagle eye. Get picture with ruler on left side next to 1kb marker.

Trim marker and excess edges out under UV light.

8. HCL WASH:

Wash in HCL (0.1M) for 10min exactly. Discard

Rinse with H2O. Put in 0.4M NaOH solution

9. TRANSFER:

Prepare transfer apparatus. Remove paraffin. Pour freshly-prepared NaOH solution half way up the apparatus. Remove all airbubbles from apparatus

Cut 3mm Whatman paper-5-6pcs per gel as well as Zetaprobe nylon membrane to size of the gel. Rinse nylon membrane in water

Transfer in the following sequence: 3mm filter paper(soaked in NaOH)-------Gel-----------------Nylon membrane (presoaked in H2O)-----------2-3pcs 3mm filter paper (soaked in NaOH)------------2 pcs dry filter paper

At each step remove all air bubbles

Put stack of paper towels and heavy book on top of transfer membrane

Transfer overnight

In the morning, remove dry filters. Remove nylon with gel and trim excess nylon off edges. Cut right-hand corners of nylon membrane according to the gel

Wick in 2X SSC buffer for 5minutes

Rinse with H2O

Put nylon membrane as "sandwich" between two pieces of dry 1.5 mm filter paper

Bake in oven for 30minutes at 80° C to crosslink DNA. Label each membrane

IF STORING, THEN WICK IN 2X SSC FOR 3MIN AND THEN SARAN WRAP AND STORE AT RT

10. PREHYBRIDIZATION:

Survey Hot Room with Geiger Counter

Start oven at hybridization temperature, usually 60° C

Thaw blotto by gentle heating in crock pot in hot room or 80° oven

Prepare nylon membrane: i) either crosslink or ii) if used before must strip membrane with Southern wash 2 before reusing

Wick membrane in 2X SSC for 5minutes

Roll each nylon membrane away from you and place in hybridization bottle. Use 2X SSC to unroll the membranes

Discard 2X SSC and put 20cc Blotto. Prehybridize for >1hr, usually 2hr (upto 48hr)

11. PROBE PREPARATION:

Use 0.5ml tube

PROBE: Probe (> 100ng/l ): x l

H20: (23-x) l

Heat 95° for 5min then on ice for 1 min

dATG mix: 6 l (dATP,dGTP,dTTP mix)

10X Hex buffer: 4 l

Klenow: 1.5 l

32P-dCTP: 5 l

Incubate probe at 37° C for 30-45 minutes

12. PROBE PURIFICATION:

Use Pharmacia S200 Microspin columns

Place each column in a 2.0 ml eppendorf tube. Spin for 2.5min at 3000rpm

Spin the probe for 2.5 min at 3000rpm

Add 60l column elution buffer to the probe. Add hot probe to the column and spin for 2.5 min at 3000rpm

Remove column carefully. Check activity of eluted probe---should be hot!

Add another 100l elution buffer to the eluate

Add 2l of probe to scintillation vial (1:100 dilution) and measure 32P activity (Program 3). Final activity is : measured CPM X 100

Boil probe for 3minutes and then on ice for 1min

Remove prehybridization buffer from hybridization bottle and add probe with Blotto (Total vol blotto: 15ml)

Hybridize overnight in oven at the desired temperature, usually 60° C

13. SOUTHERN WASH:

Prewarm wash buffers at 65° C in hot room (Southern wash solutions 1 & 2)

Decant the hybridization buffer in liquid radio waste

Rinse with 20ml Wash 1 solution. Decant into liquid waste

Wash with 2/3volume Wash 1 solution for 10minutes at 65° C X 2. Discard in sink

Rinse with 20ml Wash 2 solution. Discard in sink

Wash with 2/3 volume Wash 2 so

[1] [2] 下一页  

[收藏] [推荐] [评论(0条)] [返回顶部] [打印本页] [关闭窗口]
用户名: 新注册) 密码: 匿名评论
评论内容:(不能超过250字,需审核后才会公布,请自觉遵守互联网相关政策法规。
§最新评论:
热点文章
·电泳技术简介
·PCR反应体系与反应条件
·PCR引物设计及相关软件使用
·RNA抽提指南(TRIZOL)
·定量PCR常见问题解答
·电泳技术专题
·DNA的凝胶电泳
·聚丙烯酰胺凝胶电泳分离过氧化物
·引物设计总结
·什么是PET塑料
·透析袋概述
·PCR技术概论
相关文章
·CGH of PCR Amplified Microdiss
·Methylated CpG Island Amplific
·Extraction of RNA from Frozen
·Methylation Specific PCR
·蛋白质间相互作用研究方法1
·甲基化PCR引物设计
·在线引物设计站点
·Western杂交
·Gel Mobility Shift Assay
·Gel Shift Assay Systems
·RNA点杂交
·DNA点杂交
Power by DedeCms